Cooling tubes for piping

Round copper tubing specialised in refrigeration systems and ducting with an outer diameter of 3.18 to 108 mm.

Medidas:

Exterior Ø 3.18 to 108 mm.

Data sheet: Cooling tubes for piping

Copper tubes for air conditioning and refrigeration systems have good heat conduction and corrosion resistance properties, suitable for this type of application. In our catalogue you will find a wide range of sizes from 3.18 to 108 mm diameter with the corresponding nominal wall thickness. Various delivery options are available: in straight lengths or in coils for duct and equipment cooling. You can also use our weight calculator to determine the weight of the product by entering the material, format and type of product, as well as the dimensions to suit your needs.

In the technical data sheet section you will find details of the technical characteristics, measurements and tolerances on the external diameter and wall thickness. To guarantee a correct application, both the interior and exterior surfaces must be smooth, so that the coolant is properly distributed.

Bronmetal is ISO 9001:2015 certified, which guarantees the quality in the management of all processes with the objective of the wellbeing of our customers.

Material Designation Chemical Composition in % (m/m)
Density2 g/cm3 approx.
Symbolic Numerical Element Cu1 P
Cu-DHP
CW024A
min. 99,90 0,015
8,9
max. - 0,040
1 Including silver, up to a maximum of 0.015%.
2 Only for information.
 
Nominal exterior diameter d Nominal Wall Thickness e mm
Metric Series Imperial Series
mm mm in 0,80 1,00 1,25 1,50 1,65 2,00 2,50
3,18 1/8
3,97 5/32
4,76 3/16
6 ■ ●
6,35 1/4
7,94 5/16
8 ■ ●
9,52 3/8
10 ■ ● ■ ●
12 ■ ●
12,70 1/2 ■ ●
15 ■ ●
15,87 5/8 ■ ●
18 ■ ●
19,06 3/4
22 ■ ●
22,23 7/8
25,40 1
28
28,57 1 1/8
34,92 1 3/8
35
41,27 1 5/8
42
53,97 2 1/8
54
64
66,67 2 5/8
76,1
79,37 3 1/8
88,90 3 1/2
92,07 3 5/8
104,80 4 1/8
108
NOTE - This table is the first step towards a norm which only includes metric values.
■ Available in straight lengths.
● Available in rolls.
 

SURFACE QUALITY

The interior and exterior surfaces of the piping must be clean and smooth. Any residue left over after solvent has evaporated must not exceed 38 mg/m2 of the internal surface.
Treatment State
Tensile Strength Rm MPa min.
Elongation A % min. Hardness (indicative) HV5
Designation in line with Norm EN 1173 Common Term
R220a annealeda 220 40 (de 40 a 70)
R250 semi-hard 250 30 (de 75 a 100)
R290 hard 290 3 (min. 100)
NOTE 1 - The hardness figures in brackets are not requisites for this norm, but are given only for indicative purposes.
NOTE 2 - 1 MPa equivalent to 1N/mm2.
 

TOLERANCES ON MEAN EXTERIOR DIAMETER FOR SMOOTH PIPES

Nominal exterior diameter d Tolerances on mean diameter
greater than less than or equal to  e ≤ 0,4 0,4 mm"}"> e > 0,4 mm
6 13 ± 0,04 ± 0,04
13 16 ± 0,05 ± 0,04
16 28 - ± 0,05
28 54 - ± 0,06
54 67 - ± 0,07

TOLERANCES ON WALL THICKNESS FOR SMOOTH PIPES

Tolerances Nominal Exterior Diameter d Nominal Wall Thickness e
greater than less than or equal to 0,25 ≤ e ≤ 0,30 0,30 < e ≤ 0,35 0,35 < e ≤ 0,40 0,40 < e ≤ 0,50 0,50 < e ≤ 0,63 0,63 < e ≤ 0,80 0,80 < e ≤ 1,50 1,50 < e ≤ 2,00
Maximum deviation admissable at any pointa 6 67 ± 0,025 ± 0,03 ± 0,03 ± 0,04 ± 0,05 ± 0,06 ± 8%b ± 8%b
Tolerances for mean thickness 6 9,52 ± 0,01 ± 0,01 ± 0,01 ± 0,015 ± 0,02 ± 0,02 - -
9,52 13 - ± 0,01 ± 0,01 ± 0,015 ± 0,02 ± 0,02 - -
13 16 - - ± 0,01 ± 0,015 ± 0,02 ± 0,02 - -
16 22 - - - - - ± 0,02 ± 0,05 -
22 40 - - - - - ± 0,02 ± 0,05 -
40 67 - - - - - - - ± 0,08
a   Includes concentricity deviation.
b   Value as a percentage of nominal thickness.

Documentation download

Title
Other languages
Type
Created
Type Catalogue
Created 07/07/2020
Type Technical sheets
Created 22/04/2020
You may also like

Copper tubes for electrical applications

Copper alloy tubes

Brass tubes

Round extruded/calibrated bronze tubes